Num |
Photo |
Explanation |
1 |
|
Campbell Scientific GRANITE 9 DAQ - measurement system
• One of the most computationally powerful data-acquisition devices from Campbell Scientific
• 24 bit and 32 bit ADC
• An all-digital measurement and control DAQ
• 8x digital I/O terminals (configurable)
• 2x switched 12V
• EPI port switch for high-speed connection to all GRANITE modules
• Built-in GPS for network synchronization
• Built-in Wi-Fi
• 4 Mbytes battery-backed SRAM + 128 MB NOR flash memory, expandable to 16 GB
• Onboard storage of streaming data with 2 GB of DDR3 SDRAM and 64 GB SSD
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
|
2 |
|
Campbell Scientific GRANITE 10 DAQ - measurement system
• One of the most computationally powerful data-acquisition devices from Campbell Scientific
• 24 bit and 32 bit ADC
• An all-digital measurement and control DAQ
• 8x digital I/O terminals (configurable)
• 4 General-purpose CAN channels
• 2x switched 12V
• EPI port switch for high-speed connection to all GRANITE modules
• Built-in GPS for network synchronization
• Built-in Wi-Fi
• 4 Mbytes battery-backed SRAM + 128 MB NOR flash memory, expandable to 16 GB
• Onboard storage of streaming data with 2 GB of DDR3 SDRAM and 64 GB SSD
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
|
3 |
|
Campbell Scientific VOLT 108 - general-purpose, multiplexed analog measurement module
• General-purpose, multiplexed analog measurement module
• 8 differential or 16 single-ended input channels with 2 excitation channels
• 1x switched 12V and 2x switched 5V
• Channel count expansion via the CPI bus
• USB 2.0 interface for direct-to-PC-based operation
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
|
4 |
|
Campbell Scientific VOLT 116 - general purpose, multiplexed analog measurement module
• General-purpose, multiplexed analog measurement module
• 16 differential or 32 single-ended input channels with 2 excitation channels
• 2x switched 12V and 4x switched 5V
• Channel count expansion via the CPI bus
• USB 2.0 interface for direct-to-PC-based operation
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
|
5 |
|
Campbell Scientific TEMP 120
• Purpose-built thermocouple measurement module
• Part of a data-acquisition system such as the GRANITE Datalogger series, CR6 or CR1000X loggers
• 20 thermocouple inputs using universal copper-copper standard miniature thermocouple connectors
• Resolution of 0.015°C
• Handles extreme temperature environments and rapid thermal gradients
• Time base can be referenced either to GPS or a temperature-compensated real-time clock
• CPI DAQ connection for channel expansion
• USB 2.0 interface for PC-based operation
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
|
6 |
|
Campbell Scientific CR1000X - measurement system
• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 16x analogue single-ended or 8 differential Analog Inputs
• 10x pulse counters
• 8x digital IN/OUT (configurable)
• 4x analogue voltage (switched excitation mode or switched regulated voltage supply)
• 2x switched 12V
• RS232, CS I/O PORT to CSI peripherals, USB, Ethernet (LAN) port
• 4 Mbytes battery-backed SRAM + 72 MB flash memory, expandable to 8 GB
• Surge, Electrostatic Discharge and Lightning Protection for all critical Inputs and Outputs
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
|
7 |
|
CR1000X Datalogger Calibration - compliant to recommendations of FGW TR6, IEC and MEASNET
• Compliant to recommendations of FGW TR6, IEC and MEASNET
• Incl. calibration certificate
• Calibration standards traceable to ilac-MRA accreditation service
|
8 |
|
Campbell Scientific CR1000 - measurement system
• 16x analogue single-ended or 8 differential IN
• 2x digital pulse counters IN
• 8x digital IN/OUT
• 3x analogue voltage OUT
• 1x switched 12V OUT
• RS232
• CS I/O PORT, SDI-12, Peripheral ports
• CF-card, USB, LAN, WLAN (optional)
• 2/4 Mbytes SRAM memory
• Surge protection for all Inputs by gas discharge tube (GDT)
• Surge protection for critical outputs by GDT or transient voltage suppression diodes
• Power feeding protected by transzorb diodes
• Grounding socket for electrostatic discharge (ESD) protection
|
9 |
|
CR1000 Datalogger Calibration - compliant to recommendations of FGW TR6, IEC and MEASNET
• Compliant to recommendations of FGW TR6, IEC and MEASNET
• Incl. calibration certificate
• Calibration standards traceable to ilac-MRA accreditation services
|
10 |
|
Campbell Scientific CR6 - measurement system
• Calibration certificate
• 12x single-ended or 6xy differential freely programmable analog or digital IN & OUT
• 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V)
• 2x switched 12V OUT
• 1x RS232 / RS485
• CS I/O PORT
• LAN
• USB
• RJ-45
• Micro-SD card
• 4 Mbytes SRAM memory
• Surge protection for all Inputs by gas discharge tube (GDT)
• Surge protection for critical Oututs by GDT or transient voltage suppression diodes
• Power feeding protected by tranzorb diodes
• Grounding socket for electrostatic discharge (ESD) protection
|
11 |
|
Campbell Scientific CR6 - WIFI - measurement system
• CR6-WIFI
• Calibration certificate
• 12x single-ended or 6xy differential freely programmable analog or digital IN & OUT
• 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V)
• 2x switched 12V OUT
• 1x RS232 / RS485
• CS I/O PORT
• WLAN WIFI for short-range wireless IP communications based on 802.11 b/g/n, WPA/WPA2-Personal, WPA/WPA2-Enterprise Security, WEP
• USB
• RJ-45
• Micro-SD card
• 4 Mbytes SRAM memory
• Surge protection for all Inputs by gas discharge tube (GDT)
• Surge protection for critical Oututs by GDT or transient voltage suppression diodes
• Power feeding protected by tranzorb diodes
• Grounding socket for electrostatic discharge (ESD) protection
|
12 |
|
Campbell Scientific CR6-RF4XX - measurement system
• CR6-RF422
• Calibration certificate
• 12x single-ended or 6xy differential freely programmable analog or digital IN & OUT
• 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V)
• 2x switched 12V OUT
• 1x RS232 / RS485
• CS I/O PORT
• Internal RF422 morem or optional for specific countries: RF407, RF412, RF451
• LAN
• USB
• RJ-45
• Micro-SD card
• 4 Mbytes SRAM memory
• Surge protection for all Inputs by gas discharge tube (GDT)
• Surge protection for critical Oututs by GDT or transient voltage suppression diodes
• Power feeding protected by tranzorb diodes
• Grounding socket for electrostatic discharge (ESD) protection
|
13 |
|
CR6 (-RF422 / -WIFI) Datalogger Calibration - compliant to recommendations of FGW TR6, IEC and MEASNET
• Compliant to recommendations of FGW TR6, IEC and MEASNET
• Incl. calibration certificate
• Calibration standards traceable to ilac-MRA accreditation service
|
14 |
|
Campbell Scientific CR310 - measurement system
• Set-up easily with PC software and USB connectivity
• Ideal for small applications requiring long-term, remote monitoring and control
• Measure smart sensors using RS-232 or SDI-12
• 6x single-ended or 3x differential freely programmable analog or digital IN & OUT
• 8x pulse counting terminals with 2x control terminals
• 7x configurable digital I/O terminals
• 2x switched 12V OUT; 2x voltage excitation terminals
• 1x RS232, 1x USB Micro B, 1x 10/100 Ethernet RJ45
• 30MB serial flash memory
• Integral surge and ESD protection
• Integrated 12 V battery solar charge regulator to charge batteries
• Connect with PakBus, Modbus, DNP3, GOES, and other standard communication protocols
• Available in multiple radio, cellular network modem and Wi-Fi options that are suitable for different regions and applications
|
15 |
|
Campbell Scientific CR850 - measurement system
• 6x analog single-ended or 3 differential IN
• 2x digital pulse counters IN
• 4x digital IN/OUT
• 3x analog voltage OUT
• 1x switched 12V OUT
• RS232
• CS I/O PORT
• 2/4 Mbytes SRAM memory
• Keypad
• LCD Display
• Surge protection for all Inputs by gas discharge tube (GDT)
• Power feeding protected by tranzorb diodes
• Grounding socket for electrostatic discharge (ESD) protection
|
16 |
|
CR850 Datalogger Calibration - compliant to recommendations of FGW TR6, IEC and MEASNET
• Compliant to recommendations of FGW TR6, IEC and MEASNET
• Incl. calibration certificate
• Calibration standards traceable to ilac-MRA accreditation services
|
17 |
Campbell Scientific CR800 - measurement system |
• 6x analog single-ended or 3 differential IN
• 2x digital pulse counters IN
• 4x digital IN/OUT
• 3x analog voltage OUT
• 1x switched 12V OUT
• RS232
• CS I/O PORT
• 2/4 Mbytes SRAM memory
• Surge protection for all Inputs by gas discharge tube (GDT)
• Power feeding protected by tranzorb diodes
• Grounding socket for electrostatic discharge (ESD) protection
|
18 |
|
CR800 Datalogger Calibration - compliant to recommendations of FGW TR6, IEC and MEASNET
• Compliant to recommendations of FGW TR6, IEC and MEASNET
• Incl. calibration certificate
• Calibration standards traceable to ilac-MRA accreditation services
|
19 |
|
Ammonit Meteo-40S
• Ammonit Meteo-40S
• 4x analog voltage IN (± 0.1V, ± 1V, ± 10V 16bit)
• 1x analog current IN (± 1mA, ± 10mA, ± 100mA 16bit)
• 4x pulse counter IN
• 2x digital serial status IN
• 1 RS485 Master IN (for up to 8 smart sensors or Ultra Sonic Anemometers)
• 2x analog voltage OUT (5V | Switches)
• 1x analog current OUT
• 1 RS485 Slave OUT (SCADA monitoring software)
• 3 USB (2x USB-A host, 1x USB-B device)
• 1 LAN (Ethernet)
|
20 |
|
Ammonit Meteo-40S Plus
• Ammonit Meteo-40S Plus
• With new firmware version offering flexibility in the user setttings, sensor and modem configuration, data security, among others
• 4x analog voltage IN (± 0.1V, ± 1V, ± 10V 16bit)
• 1x analog current IN (± 1mA, ± 10mA, ± 100mA 16bit)
• 4x pulse counter IN
• 2x digital serial status IN
• 1 RS485 Master IN (for up to 8 smart sensors or Ultra Sonic Anemometers)
• 2x analog voltage OUT (5V | Switches)
• 1x analog current OUT
• 1 RS485 Slave OUT (SCADA monitoring software)
• 3 USB (2x USB-A host, 1x USB-B device)
• 1 LAN (Ethernet)
|
21 |
|
Meteo 40-S Datalogger Calibration - compliant to recommendations of FGW TR6, IEC and MEASNET
• Compliant to recommendations of FGW TR6, IEC and MEASNET
• Incl. calibration certificate
• Calibration standards traceable to DAkkS (ilac-MRA) accreditation service
|
22 |
|
Meteo 40-S Datalogger Calibration - compliant to recommendations of FGW TR6, IEC and MEASNET
• Compliant to recommendations of FGW TR6, IEC and MEASNET
• Incl. calibration certificate
• Calibration standards traceable to DAkkS (ilac-MRA) accreditation service
|
23 |
|
Ammonit Meteo-40M
• Ammonit Meteo-40M
• 8x analog voltage IN (± 0.1V, ± 1V, ± 10V 16bit)
• 1x analog current IN (± 1mA, ± 10mA, ± 100mA 16bit)
• 8x pulse counter IN
• 4x digital serial status IN
• 1 RS485 Master IN (for up to 8 smart sensors or Ultra Sonic Anemometers)
• 4x analog voltage OUT (5V | Switches)
• 1x analog current OUT
• 1 RS485 Slave OUT (SCADA monitoring software)
• 3 USB (2x USB-A host, 1x USB-B device)
• 1 LAN (Ethernet)
|
24 |
|
Ammonit Meteo-40M Plus
• Ammonit Meteo-40M Plus
• With new firmware version offering flexibility in the user setttings, sensor and modem configuration, data security, among others
• 8x analog voltage IN (± 0.1V, ± 1V, ± 10V 16bit)
• 1x analog current IN (± 1mA, ± 10mA, ± 100mA 16bit)
• 8x pulse counter IN
• 4x digital serial status IN
• 1 RS485 Master IN (for up to 8 smart sensors or Ultra Sonic Anemometers)
• 4x analog voltage OUT (5V | Switches)
• 1x analog current OUT
• 1 RS485 Slave OUT (SCADA monitoring software)
• 3 USB (2x USB-A host, 1x USB-B device)
• 1 LAN (Ethernet)
|
25 |
|
Meteo-40M Datalogger Calibration - compliant to recommendations of FGW TR6, IEC and MEASNET
• Compliant to recommendations of FGW TR6, IEC and MEASNET
• Incl. calibration certificate
• Calibration standards traceable to DAkkS (ilac-MRA) accreditation service
|
26 |
|
Meteo-40M Plus Datalogger Calibration - compliant to recommendations of FGW TR6, IEC and MEASNET
• Compliant to recommendations of FGW TR6, IEC and MEASNET
• Incl. calibration certificate
• Calibration standards traceable to DAkkS (ilac-MRA) accreditation service
|
27 |
|
Ammonit Meteo-40L
• Ammonit Meteo-40L
• 12x analog voltage IN (± 0.1V, ± 1V, ± 10V 16bit)
• 2x analog current IN (± 1mA, ± 10mA, ± 100mA 16bit)
• 12x pulse counter IN
• 8x digital serial status IN
• 1 RS485 Master IN (for up to 8 smart sensors or Ultra Sonic Anemometers)
• 8x analog voltage OUT (5V | Switches)
• 2x analog current OUT
• 1 RS485 Slave OUT (SCADA monitoring software)
• 3 USB (2x USB-A host, 1x USB-B device)
• 1 LAN (Ethernet)
|
28 |
|
Ammonit Meteo-40L Plus
• Ammonit Meteo-40L Plus
• With new firmware version offering flexibility in the user setttings, sensor and modem configuration, data security, among others
• 12x analog voltage IN (± 0.1V, ± 1V, ± 10V 16bit)
• 2x analog current IN (± 1mA, ± 10mA, ± 100mA 16bit)
• 12x pulse counter IN
• 8x digital serial status IN
• 1 RS485 Master IN (for up to 8 smart sensors or Ultra Sonic Anemometers)
• 8x analog voltage OUT (5V | Switches)
• 2x analog current OUT
• 1 RS485 Slave OUT (SCADA monitoring software)
• 3 USB (2x USB-A host, 1x USB-B device)
• 1 LAN (Ethernet)
|
29 |
|
Meteo-40L Datalogger Calibration - compliant to recommendations of FGW TR6, IEC and MEASNET
• Compliant to recommendations of FGW TR6, IEC and MEASNET
• Incl. calibration certificate
• Calibration standards traceable to DAkkS (ilac-MRA) accreditation service
|
30 |
|
Meteo-40L Plus Datalogger Calibration - compliant to recommendations of FGW TR6, IEC and MEASNET
• Compliant to recommendations of FGW TR6, IEC and MEASNET
• Incl. calibration certificate
• Calibration standards traceable to DAkkS (ilac-MRA) accreditation service
|