Num |
Photo |
Explanation |
1 |
|
Thies First Class Wind Vane
• 4.3151.10.212
• Potentiometer 0 … 2.0 kOhm = 0 … 360 degrees
• Measurement range: 0...360°
• Without north gap
• Accuracy: 0.25% (1°)
• Resolution: 0.35°
• W/o heating
|
2 |
|
Thies First Class Wind Vane - heated
• 4.3151.00.212
• Potentiometer 0 … 2.0 kOhm = 0 … 360 degrees
• Measurement range: 0...360°
• Without north gap
• Accuracy: 0.25% (1°)
• Resolution: 0.35°
• With heating (24V AC / DC, 25W)
|
3 |
|
Thies First Class Wind Vane
• 4.3151.10.312
• Potentiometer 0 … 2.0 kOhm
• Measurement range: 0...360°
• Dead zone typ. 1.5°
• Accuracy: ± 1.5°
• Linearity: 0.35% (± 1.25°)
• W/o heating
|
4 |
|
Thies First Class Wind Vane
• 4.3151.00.312
• Potentiometer 0 … 2.0 kOhm
• Measurement range: 0...360°
• Dead zone typ. 1.5°
• Accuracy: ± 1.5°
• Linearity: 0.35% (± 1.25°)
• With heating (24V AC/DC, 25W)
|
5 |
|
Thies First Class Wind Vane
• 4.3151.10.020
• Potentiometer simulator
• Measurement range: 0...360°
• Accuracy: 0.25% (1°)
• Resolution: 0.35°
• Power Supply: 3.3 ... 12 V DC
• W/o heating
|
6 |
|
Thies First Class Wind Vane - heated
• 4.3151.00.020
• Potentiometer simulator
• Measurement range: 0...360°
• Accuracy: 0.25% (1°)
• Resolution: 0.35°
• Power Supply: 3.3 ... 12 V DC
• With heating (24V AC / DC, 25W)
|
7 |
|
Thies First Class Wind Vane
• 4.3151.10.210
• Potentiometer 0 … 10.0 kOhm = 0 … 360 degrees
• Measurement range: 0...360°
• Without north gap
• Accuracy: 0.25% (1°)
• Resolution: 0.35°
• W/o heating
|
8 |
|
Thies First Class Wind Vane - heated
• 4.3151.00.210
• Potentiometer 0 … 10.0 kOhm = 0 … 360 degrees
• Measurement range: 0...360°
• Without north gap
• Accuracy: 0.25% (1°)
• Resolution: 0.35°
• With heating (24V AC / DC, 25W)
|
9 |
|
Thies First Class Wind Vane
• 4.3151.10.110
• Potentiometer 0 … 10.0 kOhm = 0 … 360 degrees
• Potentiometer protective circuit: series resistance: 50 Ω
• Measurement range: 0...360°
• Without north gap
• Accuracy: 0.25% (1°)
• Resolution: 0.35°
• W/o heating
|
10 |
|
Thies First Class Wind Vane - heated
• 4.3151.00.110
• Potentiometer 0 … 10.0 kOhm = 0 … 360 degrees
• Potentiometer protective circuit: series resistance: 50 Ω
• Measurement range: 0...360°
• Without north gap
• Accuracy: 0.25% (1°)
• Resolution: 0.35°
• With heating (24V AC / DC, 25W)
|
11 |
|
Thies First Class Wind Vane
• 4.3151.10.012
• Potentiometer 0 … 2.0 kOhm = 0 … 360 degrees
• Potentiometer protective circuit: series resistance: 50 Ω
• Measurement range: 0...360°
• Without north gap
• Accuracy: 0.25% (1°)
• Resolution: 0.35°
• W/o heating
|
12 |
|
Thies First Class Wind Vane - heated
• 4.3151.00.012
• Potentiometer 0 … 2.0 kOhm = 0 … 360 degrees
• Potentiometer protective circuit: series resistance: 50 Ω
• Measurement range: 0...360°
• Without north gap
• Accuracy: 0.25% (1°)
• Resolution: 0.35°
• With heating (24V AC / DC, 25W)
|
13 |
|
Thies First Class Wind Vane
• 4.3151.10.140
• TMR-Sensor (Tunnel Magneto Resistance)
• Measurement range: 0...360°
• Electrical output 0 ... 20 mA
• Resolution analogue = 10 bit
• Without north gap
• Accuracy: 0.25% (1°)
• Resolution: 0.35°
• W/o heating
|
14 |
|
Thies First Class Wind Vane - heated
• 4.3151.00.140
• TMR-Sensor (Tunnel Magneto Resistance)
• Measurement range: 0...360°
• Electrical output 0 ... 20 mA
• Resolution analogue = 10 bit
• Without north gap
• Accuracy: 0.25% (1°)
• Resolution: 0.35°
• With heating (24V AC / DC, 25W)
|
15 |
|
Thies First Class Wind Vane
• 4.3151.10.141
• TMR-Sensor (Tunnel Magneto Resistance)
• Measurement range: 0...360°
• Electrical output 4 ... 20 mA
• Resolution analogue = 10 bit
• Without north gap
• Accuracy: 0.25% (1°)
• Resolution: 0.35°
• W/o heating
|
16 |
|
Thies First Class Wind Vane - heated
• 4.3151.00.141
• TMR-Sensor (Tunnel Magneto Resistance)
• Measurement range: 0...360°
• Electrical output 4 ... 20 mA
• Resolution analogue = 10 bit
• Without north gap
• Accuracy: 0.25% (1°)
• Resolution: 0.35°
• With heating (24V AC / DC, 25W)
|
17 |
|
Thies First Class Wind Vane
• 4.3151.10.161
• TMR-Sensor (Tunnel Magneto Resistance)
• Measurement range: 0...360°
• Electrical output 0 ... 10 V
• Resolution analogue = 10 bit
• Without north gap
• Accuracy: 0.25% (1°)
• Resolution: 0.35°
• W/o heating
|
18 |
|
Thies First Class Wind Vane - heated
• 4.3151.00.161
• TMR-Sensor (Tunnel Magneto Resistance)
• Measurement range: 0...360°
• Electrical output 0 ... 10 V
• Resolution analogue = 10 bit
• Without north gap
• Accuracy: 0.25% (1°)
• Resolution: 0.35°
• With heating (24V AC / DC, 25W)
|
19 |
|
Thies First Class Wind Vane
• 4.3151.10.173
• TMR-Sensor (Tunnel Magneto Resistance)
• Measurement range: 0...360°
• Electrical output 0 ... 5 V
• Resolution analogue = 10 bit
• Without north gap
• Accuracy: 0.25% (1°)
• Resolution: 0.35°
• W/o heating
|
20 |
|
Thies First Class Wind Vane - heated
• 4.3151.00.173
• TMR-Sensor (Tunnel Magneto Resistance)
• Measurement range: 0...360°
• Electrical output 0 ... 5 V
• Resolution analogue = 10 bit
• Without north gap
• Accuracy: 0.25% (1°)
• Resolution: 0.35°
• With heating (24V AC / DC, 25W)
|
21 |
|
Thies First Class Wind Vane
• 4.3151.10.400
• Digital output, 8 bit (RS 485)
• Measurement range: 0...360°
• Option for connecting an anemometer „First Class 4.3351.x0.000“ (daisy chain)
• Without north gap
• Accuracy: 0.25% (1°)
• Resolution: 0.1°
• W/o heating
|
22 |
|
Thies First Class Wind Vane - heated
• 4.3151.00.400
• Digital output, 8 bit (RS 485)
• Measurement range: 0...360°
• Option for connecting an anemometer „First Class 4.3351.x0.000“ (daisy chain)
• Without north gap
• Accuracy: 0.25% (1°)
• Resolution: 0.1°
• With heating (24V AC / DC, 25W)
|
23 |
|
Thies First Class Wind Vane - TMR
• 4.3151.10.901
• TMR-Sensor (Tunnel Magneto Resistance)
• Measurement range: 0...360°
• Digital output protocoll: 16 bit serial synchronous
• Digital output: 10 bit Gray Code
• Without north gap
• Accuracy: 0.75°
• Resolution: 0.35°
• W/o heating
|
24 |
|
Thies First Class Wind Vane - TMR - heated
• 4.3151.00.901
• TMR-Sensor (Tunnel Magneto Resistance)
• Measurement range: 0...360°
• Digital output protocoll: 16 bit serial synchronous
• Digital output: 10 bit Gray Code
• Without north gap
• Accuracy: 0.75°
• Resolution: 0.35°
• With heating (25W)
|
25 |
|
Thies First Class Wind Vane - TMR
• 4.3151.10.001
• TMR-Sensor (Tunnel Magneto Resistance)
• Measurement range: 0...360°
• Digital output protocoll: 16 bit serial synchronous
• Digital output: 10 bit Gray Code
• Without north gap
• Accuracy: 0.75°
• Resolution: 0.35°
• W/o heating
|
26 |
|
Thies First Class Wind Vane - TMR - heated
• 4.3151.00.001
• TMR-Sensor (Tunnel Magneto Resistance)
• Measurement range: 0...360°
• Digital output protocoll: 16 bit serial synchronous
• Digital output: 10 bit Gray Code
• Without north gap
• Accuracy: 0.75°
• Resolution: 0.35°
• With heating (25W)
|