Num |
Photo |
Explanation |
1 |
|
Thies First Class Advanced Anemometer (MEASNET calibrated) - unheated
- - 4.3351.10.000 - unheated
- - Frequency output (1082 Hz at 50 m/s)
- - Class A compliance in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
- - 4Supply 3.3 ... 42 V DC
- - easurement Range: 0.3...75 m/s
- - Accuracy: 1% of value or <0.2 m/s (0.3...50m/s)
- - Linearity: r>0.99999 (4...20 m/s)
- - W/o heating
|
2 |
|
Thies First Class Advanced Anemometer (MEASNET calibrated) - heated
- - 4.3351.00.000 - heated
- - Frequency output (1082 Hz at 50 m/s)
- - Class A compliance in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
- - 4Supply 3.3 ... 42 V DC
- - Measurement Range: 0.3...75 m/s
- - Accuracy: 1% of value or <0.2 m/s (0.3...50m/s)
- - Linearity: r>0.99999 (4...20 m/s)
- - With heating (24V AC/DC, 25W)
|
3 |
|
Thies First Class Advanced II Anemometer (MEASNET calibrated) - unheated
- - 4.3352.10.000 - unheated
- - Frequency output (1082 Hz at 50 m/s)
- - Class A compliance in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
- - 4Supply 3.3 ... 48 V DC
- - Measurement Range: 0.3...75 m/s
- - Accuracy: <1% of value or < ±0.2 m/s (0.3...50m/s)
- - Linearity: r>0.99999 (4...20 m/s)
|
4 |
|
Thies First Class Advanced II Anemometer (MEASNET calibrated) - heated
- - 4.3352.00.000 - heated
- - Frequency output (1082 Hz at 50 m/s)
- - Class A compliance in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
- - 4Supply 3.3 ... 48 V DC
- - Measurement Range: 0.3...75 m/s
- - Accuracy: <1% of value or < ±0.2 m/s (0.3...50m/s)
- - Linearity: r>0.99999 (4...20 m/s)
|
5 |
|
Thies First Class Advanced Anemometer X (MEASNET calibrated) - unheated
- - 4.3352.10.400 - unheated
- - Frequency output (1082 Hz at 50 m/s)
- - Class A compliance in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
- - W/o heating
- - Measurement Range: 0.3...75 m/s
- - Outputs: RS485 / ASCII / MODBUS
- - Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain)
- - Measures next to wind speed also:
Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C)
Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °)
Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz)
Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
|
6 |
|
Thies First Class Advanced X Anemometer (MEASNET calibrated) - heated
- - 4.3352.00.400 - heated
- - Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2
- - With heating (24V AC/DC, 25W)
- - Measurement Range: 0.3...75 m/s
- - Outputs: RS485 / ASCII / MODBUS
- - Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain)
- - Measures next to wind speed also:
Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C)
Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °)
Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz)
Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
|
7 |
|
Thies First Class Advanced Anemometer X (MEASNET calibrated) - unheated
- - 4.3352.10.401 - unheated
- - Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2
- - W/o heating
- - Measurement Range: 0.3...75 m/s
- - Outputs: RS485 / ASCII / MODBUS
- - Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain)
- - Measures next to wind speed also:
Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C)
Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °)
Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz)
Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
|
8 |
|
Thies First Class Advanced Anemometer X (MEASNET calibrated) - heated
- - 4.3352.00.401 - heated
- - Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2
- - With heating (24V AC/DC, 25W)
- - Measurement Range: 0.3...75 m/s
- - Outputs: RS485 / ASCII / MODBUS
- - Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain)
- -Measures next to wind speed also:
Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C)
Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °)
Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz)
Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
|
9 |
|
Thies First Class Advanced Anemometer (MEASNET calibrated)
- - 4.3351.10.140
- - Frequency output (1082 Hz at 50 m/s)
- - Analogue output (0 ... 20 mA = 0.3...75 m/s)
- - Supply 15 ... 24 V DC
- - W/o heating
|
10 |
|
Thies First Class Advanced Anemometer (MEASNET calibrated)
- - 4.3351.00.140
- - Frequency output (1082 Hz at 50 m/s)
- - Analogue output (0 ... 20 mA = 0.3...75 m/s)
- - Supply 15 ... 24 V DC
- - Heated
|
11 |
|
Thies First Class Advanced Anemometer (MEASNET calibrated)
- - 4.3351.10.141
- - Frequency output (1082 Hz at 50 m/s)
- - Analogue output (4 ... 20 mA = 0.3...75 m/s)
- - Supply 15 ... 24 V DC
- - W/o heating
|
12 |
|
Thies First Class Advanced Anemometer (MEASNET calibrated)
- - 4.3351.00.141
- - Frequency output (1082 Hz at 50 m/s)
- - Analogue output (4 ... 20 mA = 0.3...75 m/s)
- - Supply 15 ... 24 V DC
- - Heated
|
13 |
|
Thies First Class Advanced Anemometer (MEASNET calibrated)
- - 4.3351.10.161
- - Frequency output (1082 Hz at 50 m/s)
- - Analogue output (0 ... 10 V = 0.3...75 m/s)
- - Supply 15 ... 24 V DC
- - W/o heating
|
14 |
|
Thies First Class Advanced Anemometer (MEASNET calibrated)
- - 4.3351.00.161
- - Frequency output (1082 Hz at 50 m/s)
- - Analogue output (0 ... 10 V = 0.3...75 m/s)
- - Supply 15 ... 24 V DC
- - Heated
|
15 |
|
Thies Compact Anemometer)
- - 4.3520.10.000
- - Measurement Range: 0.5...50 m/s
- - Accuracy: ± 0.5 m/s or 3% of measuremet value
- - Resolution: 0.1 m/s
- - Frequency output (2 - 573 Hz)
- - Supply 15 ... 28 V DC
- - W/o heating
- - Opto-electronic principle
|
16 |
|
Thies Compact Anemometer - heated
- - 4.3520.00.000
- - Measurement Range: 0.5...50 m/s
- - Accuracy: ± 0.5 m/s or 3% of measuremet value
- - Resolution: 0.1 m/s
- - Frequency output (2 - 573 Hz)
- - Supply 15 ... 28 V DC
- - W/o heating
- - Opto-electronic principle
|
17 |
|
WAA151
- - Measurement Range: 0.4...75 m/s
- - With heated shaft
- - Operating power supply: Uin = 9.5 ... 15.5 VDC, 20 mA typical
- - Heating power supply: 20 V DC / AC, 10W, 500 mA nominal
|
18 |
|
Vaisala WAA252 - fully heated
WAA252
- - Measurement Range: 0.4...75 m/s
- - Fully heated: body, shaft, rotor and cups
- - Operating power supply: Uin = 24VDC ± 10%, max. 3.2A
|
19 |
|
Vector Instruments (Windspeed Ltd.) Anemometer: A100R/K
- - A100R/K
- - Switching anemometer (reed switch)
- - First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
|
20 |
|
Vector Instruments (Windspeed Ltd.) Anemometer: A100LM
- - A100LM
- - Low power pulse output (10 Hz per m/s)
- - First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
|
21 |
|
Vector Instruments (Windspeed Ltd.) Anemometer: A100LM with anti-surge protection
- - A100LM/PC3
- - Low power pulse output (10 Hz per m/s)
- - Anti-surge option: protects the electronics in the device against any surges voltages/currents induced in the instrument cable by a nearby lightning strike.
- First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
|
22 |
|
Vector Instruments (Windspeed Ltd.) Anemometer: A100LK
- - A100LK
- - Low power pulse output (10 Hz per knot)
- - First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
|
23 |
|
Vector Instruments (Windspeed Ltd.) Anemometer: A100LK with anti-surge protection
- - A100LK/PC3
- - Low power pulse output (10 Hz per knot)
- - Anti-surge option: protects the electronics in the device against any surges voltages/currents induced in the instrument cable by a nearby lightning strike.
- First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
|
24 |
|
Vector Instruments (Windspeed Ltd.) Anemometer: A100L2
- - A100L2/PC3
- - Low power pulse frequency
- - Analogue Voltage output
- - Anti-surge option: protects the electronics in the device against any surges voltages/currents induced in the instrument cable by a nearby lightning strike.
- - First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
|
25 |
|
Vector Instruments (Windspeed Ltd.) Anemometer: A100L2 with anti-surge protection
- - 100L2/PC3
- - Low power pulse frequency
- - Analogue Voltage output
- - Anti-surge option: protects the electronics in the device against any surges voltages/currents induced in the instrument cable by a nearby lightning strike.
- - First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
|
26 |
|
Vector Instruments (Windspeed Ltd.) Anemometer: A100AC
- - A100AC
- - Low power
- - Low level AC output (1.55 Hz per m/s)
- - First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
|
27 |
|
WindSensor P2546A OPR Anemometer
- - Calibrated according to IEC and MEASNET standard
- - First Class in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
- - Measurement Range: <0.4...75 m/s
- - Self-excited (pull-up resistor of 10…100 kΩ required)
|
28 |
|
WindSensor P2546D OPR Anemometer
- - Calibrated according to IEC and MEASNET standard
- - First Class in accordance to IEC 61400-12-1
- - Measurement Range: <0.3...75 m/s
- - Resolution: 0.001 m/s @ 10-minute average mode
- - Self-excited (pull-up resistor of 10…100 kΩ required)
|
29 |
|
WindSensor P2546D OPR Anemometer
- - alibrated according to IEC and MEASNET standard
- - First Class in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
- - Measurement Range: <0.4...75 m/s
- - Resolution: 0.001 m/s @ 10-minute average mode
- - Self-excited , no external power supply required)
|