ANEMOMETERHOME

본문 바로가기
Num Photo Explanation
1

Thies First Class Advanced Anemometer (MEASNET calibrated) - unheated

  • - 4.3351.10.000 - unheated
  • - Frequency output (1082 Hz at 50 m/s)
  • - Class A compliance in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
  • - 4Supply 3.3 ... 42 V DC
  • - easurement Range: 0.3...75 m/s
  • - Accuracy: 1% of value or <0.2 m/s (0.3...50m/s)
  • - Linearity: r>0.99999 (4...20 m/s)
  • - W/o heating
2

Thies First Class Advanced Anemometer (MEASNET calibrated) - heated

  • - 4.3351.00.000 - heated
  • - Frequency output (1082 Hz at 50 m/s)
  • - Class A compliance in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
  • - 4Supply 3.3 ... 42 V DC
  • - Measurement Range: 0.3...75 m/s
  • - Accuracy: 1% of value or <0.2 m/s (0.3...50m/s)
  • - Linearity: r>0.99999 (4...20 m/s)
  • - With heating (24V AC/DC, 25W)
3

Thies First Class Advanced II Anemometer (MEASNET calibrated) - unheated

  • - 4.3352.10.000 - unheated
  • - Frequency output (1082 Hz at 50 m/s)
  • - Class A compliance in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
  • - 4Supply 3.3 ... 48 V DC
  • - Measurement Range: 0.3...75 m/s
  • - Accuracy: <1% of value or < ±0.2 m/s (0.3...50m/s)
  • - Linearity: r>0.99999 (4...20 m/s)
4

Thies First Class Advanced II Anemometer (MEASNET calibrated) - heated

  • - 4.3352.00.000 - heated
  • - Frequency output (1082 Hz at 50 m/s)
  • - Class A compliance in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
  • - 4Supply 3.3 ... 48 V DC
  • - Measurement Range: 0.3...75 m/s
  • - Accuracy: <1% of value or < ±0.2 m/s (0.3...50m/s)
  • - Linearity: r>0.99999 (4...20 m/s)
5

Thies First Class Advanced Anemometer X (MEASNET calibrated) - unheated

  • - 4.3352.10.400 - unheated
  • - Frequency output (1082 Hz at 50 m/s)
  • - Class A compliance in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
  • - W/o heating
  • - Measurement Range: 0.3...75 m/s
  • - Outputs: RS485 / ASCII / MODBUS
  • - Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain)
  • - Measures next to wind speed also: Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C) Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °) Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz) Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
6

Thies First Class Advanced X Anemometer (MEASNET calibrated) - heated

  • - 4.3352.00.400 - heated
  • - Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2
  • - With heating (24V AC/DC, 25W)
  • - Measurement Range: 0.3...75 m/s
  • - Outputs: RS485 / ASCII / MODBUS
  • - Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain)
  • - Measures next to wind speed also: Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C) Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °) Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz) Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
7

Thies First Class Advanced Anemometer X (MEASNET calibrated) - unheated

  • - 4.3352.10.401 - unheated
  • - Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2
  • - W/o heating
  • - Measurement Range: 0.3...75 m/s
  • - Outputs: RS485 / ASCII / MODBUS
  • - Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain)
  • - Measures next to wind speed also: Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C) Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °) Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz) Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
8

Thies First Class Advanced Anemometer X (MEASNET calibrated) - heated

  • - 4.3352.00.401 - heated
  • - Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2
  • - With heating (24V AC/DC, 25W)
  • - Measurement Range: 0.3...75 m/s
  • - Outputs: RS485 / ASCII / MODBUS
  • - Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain)
  • -Measures next to wind speed also: Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C) Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °) Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz) Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
9

Thies First Class Advanced Anemometer (MEASNET calibrated)

  • - 4.3351.10.140
  • - Frequency output (1082 Hz at 50 m/s)
  • - Analogue output (0 ... 20 mA = 0.3...75 m/s)
  • - Supply 15 ... 24 V DC
  • - W/o heating
10

Thies First Class Advanced Anemometer (MEASNET calibrated)

  • - 4.3351.00.140
  • - Frequency output (1082 Hz at 50 m/s)
  • - Analogue output (0 ... 20 mA = 0.3...75 m/s)
  • - Supply 15 ... 24 V DC
  • - Heated
11

Thies First Class Advanced Anemometer (MEASNET calibrated)

  • - 4.3351.10.141
  • - Frequency output (1082 Hz at 50 m/s)
  • - Analogue output (4 ... 20 mA = 0.3...75 m/s)
  • - Supply 15 ... 24 V DC
  • - W/o heating
12

Thies First Class Advanced Anemometer (MEASNET calibrated)

  • - 4.3351.00.141
  • - Frequency output (1082 Hz at 50 m/s)
  • - Analogue output (4 ... 20 mA = 0.3...75 m/s)
  • - Supply 15 ... 24 V DC
  • - Heated
13

Thies First Class Advanced Anemometer (MEASNET calibrated)

  • - 4.3351.10.161
  • - Frequency output (1082 Hz at 50 m/s)
  • - Analogue output (0 ... 10 V = 0.3...75 m/s)
  • - Supply 15 ... 24 V DC
  • - W/o heating
14

Thies First Class Advanced Anemometer (MEASNET calibrated)

  • - 4.3351.00.161
  • - Frequency output (1082 Hz at 50 m/s)
  • - Analogue output (0 ... 10 V = 0.3...75 m/s)
  • - Supply 15 ... 24 V DC
  • - Heated
15

Thies Compact Anemometer)

  • - 4.3520.10.000
  • - Measurement Range: 0.5...50 m/s
  • - Accuracy: ± 0.5 m/s or 3% of measuremet value
  • - Resolution: 0.1 m/s
  • - Frequency output (2 - 573 Hz)
  • - Supply 15 ... 28 V DC
  • - W/o heating
  • - Opto-electronic principle
16

Thies Compact Anemometer - heated

  • - 4.3520.00.000
  • - Measurement Range: 0.5...50 m/s
  • - Accuracy: ± 0.5 m/s or 3% of measuremet value
  • - Resolution: 0.1 m/s
  • - Frequency output (2 - 573 Hz)
  • - Supply 15 ... 28 V DC
  • - W/o heating
  • - Opto-electronic principle
17

WAA151

  • - Measurement Range: 0.4...75 m/s
  • - With heated shaft
  • - Operating power supply: Uin = 9.5 ... 15.5 VDC, 20 mA typical
  • - Heating power supply: 20 V DC / AC, 10W, 500 mA nominal
18

Vaisala WAA252 - fully heated

WAA252

  • - Measurement Range: 0.4...75 m/s
  • - Fully heated: body, shaft, rotor and cups
  • - Operating power supply: Uin = 24VDC ± 10%, max. 3.2A
19

Vector Instruments (Windspeed Ltd.) Anemometer: A100R/K

  • - A100R/K
  • - Switching anemometer (reed switch)
  • - First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
20

Vector Instruments (Windspeed Ltd.) Anemometer: A100LM

  • - A100LM
  • - Low power pulse output (10 Hz per m/s)
  • - First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
21

Vector Instruments (Windspeed Ltd.) Anemometer: A100LM with anti-surge protection

  • - A100LM/PC3
  • - Low power pulse output (10 Hz per m/s)
  • - Anti-surge option: protects the electronics in the device against any surges voltages/currents induced in the instrument cable by a nearby lightning strike.
  • First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
22

Vector Instruments (Windspeed Ltd.) Anemometer: A100LK

  • - A100LK
  • - Low power pulse output (10 Hz per knot)
  • - First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
23

Vector Instruments (Windspeed Ltd.) Anemometer: A100LK with anti-surge protection

  • - A100LK/PC3
  • - Low power pulse output (10 Hz per knot)
  • - Anti-surge option: protects the electronics in the device against any surges voltages/currents induced in the instrument cable by a nearby lightning strike.
  • First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
24

Vector Instruments (Windspeed Ltd.) Anemometer: A100L2

  • - A100L2/PC3
  • - Low power pulse frequency
  • - Analogue Voltage output
  • - Anti-surge option: protects the electronics in the device against any surges voltages/currents induced in the instrument cable by a nearby lightning strike.
  • - First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
25

Vector Instruments (Windspeed Ltd.) Anemometer: A100L2 with anti-surge protection

  • - 100L2/PC3
  • - Low power pulse frequency
  • - Analogue Voltage output
  • - Anti-surge option: protects the electronics in the device against any surges voltages/currents induced in the instrument cable by a nearby lightning strike.
  • - First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
26

Vector Instruments (Windspeed Ltd.) Anemometer: A100AC

  • - A100AC
  • - Low power
  • - Low level AC output (1.55 Hz per m/s)
  • - First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
27

WindSensor P2546A OPR Anemometer

  • - Calibrated according to IEC and MEASNET standard
  • - First Class in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
  • - Measurement Range: <0.4...75 m/s
  • - Self-excited (pull-up resistor of 10…100 kΩ required)
28

WindSensor P2546D OPR Anemometer

  • - Calibrated according to IEC and MEASNET standard
  • - First Class in accordance to IEC 61400-12-1
  • - Measurement Range: <0.3...75 m/s
  • - Resolution: 0.001 m/s @ 10-minute average mode
  • - Self-excited (pull-up resistor of 10…100 kΩ required)
29

WindSensor P2546D OPR Anemometer

  • - alibrated according to IEC and MEASNET standard
  • - First Class in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
  • - Measurement Range: <0.4...75 m/s
  • - Resolution: 0.001 m/s @ 10-minute average mode
  • - Self-excited , no external power supply required)